1 m
Fig. 1: Case lifter with identifi ed danger area
(yellow/black)
Note:
Observe minimum spacing
requirements according to
DIN EN 349 – Table 1, for
workstation design.
2.9.2
Identifi cation of danger areas
The system owner must mark the danger area on the case lifter and ensure that
the manner in which it positions objects does not present any shearing, impact, or
crushing hazards for personnel!
Also observe the suggestions illustrated in Fig. 1 and Fig. 2:
• Free-standing application (Fig. 1)
• Operation next to a workstation (Fig. 2)
Hazards to personnel must be ruled out!
1 m
358 709-01
Fig. 2: Operation next to a workstation with indicated safe distances
Body part
Body
Foot
Arm
Fig. 3: Excerpt from DIN EN 349 – Table 1
≥ 120 mm
Minimum distance a (mm)
500
120
120
3 842 358 712/2014-01, MPS, Bosch Rexroth AG
Notes on Safety
11/28
1 m
358 709-02
Picture