24/28
Decommissioning
Bosch Rexroth AG, MPS, 3 842 358 712/2014-01
11 Decommissioning
No special steps are required to decommission the case lifter forks. As a result, this
chapter does not contain any further information.
How to disassemble the case lifter forks is described in chapter 12 "Disassembly and
Exchange" on page 24.
Comply with the specifi cations in chapter 6 "Transport and Storage" on page 15
when transporting or storing the case lifter forks.
12 Disassembly and Exchange
12.1 Disassembly
High electrical voltage!
Danger of severe injuries or death due to electric shock.
Make sure the relevant system component is not under pressure or voltage
before electrically connecting, assembling, or disassembling the product.
Protect the system against being switched on.
The case lifter can topple!
Persons may be injured and the case lifter damaged.
Always secure the case lifter to prevent toppling.
12.1.1
Disassembling and exchanging accessories
1.
Move the forks into a suitable position.
2.
Switch the case lifter off and disconnect it from the power supply.
3.
Disassemble the mounted accessories and, if needed, assemble the new
components as described under "Assembly" on page 17.
12.1.2
Disassembling the case lifter
Disassembly is limited to only disassembling the accessories.
The case lifter itself does not need to be disassembled.
Comply with the specifi cations in chapter 6 "Transport and Storage" on page 15
when transporting or storing the case lifter.
WARNING