Seq
Indication on the Display / Action
11
If necessary, modify the content of "P0402 –
Motor rated rotation", or press the key for
the next parameter.
12
If necessary, modify the content of "P0403 –
Motor rated frequency", or press the Key for
the next parameter.
13
If necessary, modify the content of "P0404 –
Motor rated power", or press the key for the
next parameter.
14
If necessary, modify the content of "P0407 –
Motor rated power factor", or press the key
for the next parameter.
15
At this point, the HMI shows the option to do the
self-adjustment. Whenever possible, perform
the self-adjustment. Thus, to activate the self-
adjustment, change the value of P0408 to "1".
Figure 5.3 (cont.): Sequence of the Startup group for V V W control
Powering up and Startup
Seq
Indication on the Display / Action
16
During the Self-Adjustment the HMI will
simultaneously indicate the status of
"RUN" and "CONF".
17
At the end of the Self-Adjustment, the value
of P0408 automatically returns to "0", as
well as the Status of "RUN" and "CONF"
are cleared.
Press the key for the next parameter.
18
The result of Self-Adjustment is the value
in ohms of the motor stator resistance
shown in P0409.
This is the last parameter of the Self-
Adjustment of the V V W control mode.
Press the key to return to initial
parameter P0202.
19
To exit the STARTUP menu, just press
BACK/ESC.
20
Through the keys and , select the
desired menu or press the key BACK/ESC
again to return directly to the monitoring
mode of the HMI.
CFW501 | 31