Set QUIET function (reduces the noise generated by the indoor unit):

The system envisages two different types of operation: "QUIET" and "AUTO QUIET", which differ in terms of the logic they use
to manage fan speed. To set this function, perform the following operations:
(1)
Press the "FUNCTION" button until one of the "QUIET" function icons is displayed (
speed to minimum, thereby ensuring the lowest possible noise level; or "AUTO QUIET" (
in relation to the difference between indoor temperature and the operating setting, in accordance with the following Cooling
conditions:
• If the indoor air Temperature is higher than the setting temperature + 2°C, MEDIUM speed will be set;
• If the indoor air Temperature is lower or equal to the setting temperature + 2°C, MINIMUM speed will be set;
Or Heating conditions:
• If the indoor air Temperature is lower than the setting temperature -2°C, MEDIUM speed will be set;
• If the indoor air Temperature is higher than the setting temperature -2°C, MINIMUM speed will be set;
at this stage, the selected icon will begin to fl ash, indicating that the chosen low noise function mode selected is active;
(2)
press buttons (
(3)
press the "SWING/ENTER" button again to activate the selected function;
(1)
(3)
58
) or (
) respectively to switch from "QUIET" to "AUTO QUIET" function;
); this function directly sets fan
); this function manages fan speed
(2)
WARNING: to disac vate this func on,
press the "FUNCTION" bu on un l the
func on to be cancelled is selected and then
press the "SWING/ENTER" button