AERMEC WRC1 Manual De Usario página 70

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
Set the number
of units in the
group
Set unit of
measure
Parameter
reserved
Parameter not
Set type of
clock
Set repetition of
time settings
Cool set for
AUTO mode
70
00: test disengaged
01
01-16: group with ...
00
05
---
used
00: countdown
00
00: repetition disen-
00
01: repetition enabled
25°C
17°C~30°C
(77°F)
(63°F~86°F)
This parameter performs a test on the group (if a group has
been created) in order to specify how many indoor units
belong to it. This test checks whether the number set in the
parameter matches the number of units detected by the
system in the group; if this function is disengaged (value
00) and the wired panel manages a group, no alarms will
be displayed for any malfunctions in this group; to set the
parameter, proceed as follows:
units
(1) Select the operating parameter "P14";
(2) Press the "MODE" button to enter the parameter modify
mode;
(3) Press the arrow buttons to set the required value;
(4) Press the "SWING/ENTER" button to return to the list of
operating parameters
This parameter specifies which unit of measure is used to
display temperatures; to set the parameter, proceed as
follows:
(1) Select the operating parameter "P16";
00: °C
(2) Press the "MODE" button to enter the parameter modify
01: °F
mode;
(3) Press the arrow buttons to set the required value;
(4) Press the "SWING/ENTER" button to return to the list of
operating parameters
---
---
---
---
This parameter is used to select which type of clock must be
activated on the system; possible modes are:
• COUNTDOWN: management of timed actions after a cer-
tain number of hours (for more information about this mode,
refer to page 15 in this manual);
• STANDARD CLOCK: management of timed operations
using the system clock (this clock must be updated by the
user. For more information in this regard, refer to page 16 in
01: clock
this manual);
to set the parameter, proceed as follows:
(1) Select the operating parameter "P33";
(2) Press the "MODE" button to enter the parameter modify
mode;
(3) Press the arrow buttons to set the required value;
(4) Press the "SWING/ENTER" button to return to the list of
operating parameters
This parameter is used to set (only if parameter P33 is set
with the value 01) the repetition of time settings; if the rep-
etition function is disengaged, the time settings will be per-
formed only once and they will have to be set again every
day; to set the parameter, proceed as follows:
gaged
(1) Select the operating parameter "P34";
(2) Press the "MODE" button to enter the parameter modify
mode;
(3) Press the arrow buttons to set the required value;
(4) Press the "SWING/ENTER" button to return to the list of
operating parameters
This parameter is used to define a cool set-point used in
AUTO mode (reminder: the auto mode is only available on
the master unit); to set the parameter, proceed as follows:
(1) Select the operating parameter "P37";
(2) Press the "MODE" button to enter the parameter modify
mode;
(3) Press the arrow buttons to set the required value;
(4) Press the "SWING/ENTER" button to return to the list of
operating parameters

Publicidad

Tabla de contenido
loading

Tabla de contenido