CONNECTOR: SUB-D TYPE 9 PINS
• Pin 2: Rx
• Pin 3: Tx
• Pin 5: GND
The data formats for the normal operations of weighing, counting mode and accumulation of total memory will be different.
Examples:
FRAME: WEIGHING MODE
,
Head 1
FRAME: PIECE COUNTING MODE
P
C
S
:
NORMAL OUTPUT
GS
Nº
Total
<CR> <LF>
<CR> <LF>
TO MAKE THE PARTS COUNTING, WILL BE PRINTED ON UNIT WEIGHT AND THE COUNT
GS
U.W.
PCS
<CR> <LF>
<CR> <LF>
RETRIEVING THE TOTAL WEIGHT STORED IN THE MEMORY OF ACCUMULATION, THE OUTPUT FORMAT IS:
***************
TOTAL
Nº
Peso
<CR> <LF>
<CR> <LF>
10. CALIBRATION
•
Turn it on again, and during the count from 9 to 0 press the key
•
The display will show "CAL" for a few seconds. While it shows "CAL", press the keys
in the calibration section. The display will show "unload".
•
Remove any weight that is placed on the platform. Press the key
•
The display will show the last calibration weight used. If this weight is correct you can keep pressing the key
-/_
Head 2
12,340kg
GS for gross weight, NT for net weight and a unit of weight.
1
This number increases each time a new value will be stored in the
memory.
12,340kg
Total value stored in memory.
Includes 2 characters line change.
12,340kg
GS for gross weight, NT for net weight and a unit of weight.
123,4g/pcs The average weight per piece counted by the balance.
100pcs
The total number of pieces counted.
Includes 2 characters line change.
It shows a line of stars
Includes 2 characters line change
5
21,455kg
(Only personal authorized technician JUMPER K1)
Weighing date
QTY
C
.
.
USER'S MANUAL BR40
k
g
Weighing unit
_
P
C
S
-QTY UNITS-
,
and
In this same sequence to enter
. If it is not correct, use
EN
CR
LF
Terminator
CR
LF