8 .3 .1 Troubleshooting a cable-tie malfunction
Be sure to check the information on the display, à „Display
messages" on page 22.
If the cable ties are pulled in at an angle:
f Switch the power pack CPK OFF.
15
f Push trigger for bandoleer cutter
f Press gate release button
f Open gate
.
1
16
f Press release button for front cover
f Open the front cover.
f Open the rear cover.
17
f Turn drum
past the point of indexing resistance and
5
remove the cable-tie residues.
f Close the front and rear covers.
f Switch the power pack CPK ON.
f Press the Reset button.
AT2000 CPK • Operating Instructions • 04-2015 • 106-29004
1
to the left.
2
.
3
4
.
4
5
f Close the gate.
f Load new cable ties, à „Loading cable ties" on
page 12.
f Close the two covers.
8 .3 .2 Changing back-up battery
DANGER
A hazardous electrical current flows though the body
in direct or indirect contact with electrically live parts .
Electric shock, burns or death can result.
2
f Always have work on the electrical supply and on parts
that are live when the device is in operation carried out
3
by a person duly authorised to work on low-voltage
electrical equipment.
f Use only OEM fuses of the specified amperage.
f Have faulty electrical components replaced immediately.
f Always disconnect the plug from the power-supply outlet
before starting maintenance work and troubleshooting.
f Check the electrical equipment of the device at regular
intervals. Have defects such as loose connections or
scorched wiring repaired immediately.
f Switch the power pack CPK OFF.
f Disconnect the power cord from the power-supply outlet.
18
1
A T
2 0
0 0
C P
K
P o
w e
r P
a c
k
2
D a
ta
S ig
n a
l
P o
w e
r
f Remove four housing screws
f Remove housing
64
f Change back-up battery
f Refit the housing and secure it by tightening four
housing screws
1
f Set the date and time, à „Date / time" on page 15.
Troubleshooting
.
1
from the power pack CPK.
2
.
3
.
1
3
25