To reduce the risks associated with chemical exposure, impact, crush,
tipping hazards, property damage from product loss, bypass or cross
contamination due to pressure barrier failure, connector failure,
purifi cation media or capsule failure:
• Use the installation procedure specifi ed in Operation Instructions.
• Wear Personal Protective Equipment (PPE) to prevent chemical splash.
• The capsule must be subjected to a preconditioning fl ush prior to use. Use
the procedure specifi ed in Operation Instructions.
• After pre-use NaOH sanitization, fl ush the system with appropriate aqueous
buff er until the pH range of 5 to 9 has been attained and monitor the pH of
the capsule effl uent to determine when the baseline has been reached
(e.g., ± 0.5 pH units from the pH of the buff er used to fl ush the media).
• Capsules are designed for single use only. Do not reuse.
• Do not modify or alter the capsules.
• Do not put this product into service if any damage is occurred to the
capsule or any of the connecting parts.
• Do not install where fl uid pressure exceeds 3.4 bar (50 psig).
• Do not use in organic solvent based processing.
• Use only with aqueous based process fl uids in the pH range of 5 to 9.
• Do not use with or expose this product to hot liquids >40°C (104°F).
• Do not use the product on unleveled surfaces.
• Do not use the product for more than 8 hours.