Troubleshooting; Product Specifications - Mosa GE 2000 BI Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

troubleshooting

Problem
engine is running, but no ac output is
available.
engine runs good at no-load but "bogs
down" when loads are connected.
engine will not start; shuts down when
running or starts and runs rough.
engine lacks power.
engine "hunts" or falters.

Product specifications

Starting Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,000 Watts
Wattage* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,600 Watts
Load Current:
at 230 Volts AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.0 Amps
at 12 Volts DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Amps
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hertz
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single Phase
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105.6 cc (6.44 cu. in.)
Spark Plug Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.6-0.7 mm (0.023-0.027 in.)
Intake Valve Clearance . . . . . . . . . . . . . . . . 0.08 - 0.12 mm (0.0031 - 0.0047 in.) cold
Exhaust Valve Clearance . . . . . . . . . . . . . . 0.13 - 0.17 mm (0.0051 - 0.0067 in.) cold
Fuel Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.7 L (1.0 U.S. gallon)
Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.4 Liters (13.5 Ounces)
* This generator is rated in accordance with ISO 8528 G3.
12
cause
1. Red overload alarm light is on. Generator is overloaded.
2. Green output indicator light not on. Fault in generator.
3. Poor connection or defective extension cable.
4. Connected device is bad.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
1. Engine switch set to off position (o).
2. Fuel cap vent lever is in off position (o).
3. Low oil indicator light comes on. Low oil level.
4. Dirty air cleaner.
5. Out of fuel.
6. Stale fuel.
7. Spark plug wire not connected to spark plug.
8. Bad spark plug.
9. Water in fuel.
10. Flooded.
11. Excessively rich fuel mixture.
12. Intake valve stuck open or closed.
13. Engine has lost compression.
1. Load is too high.
2. Dirty air filter.
Carburetor is running too rich or too lean.
correction
1. See Don't Overload Generator in Operation section.
Shut down generator and restart.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in good condition.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. See Don't Overload Generator in Operation section.
4. Contact authorized service facility.
1. Set engine switch to on position (i).
2. Turn fuel cap vent lever to on position (i).
3. Fill crankcase to proper level or place generator on
level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Drain fuel tank and carburetor; fill with fresh fuel.
7. Connect wire to spark plug.
8. Replace spark plug.
9. Drain fuel tank and carburetor; fill with fresh fuel.
10. Wait 5 minutes and re-crank engine.
11. Contact authorized service facility.
12. Contact authorized service facility.
13. Contact authorized service facility.
1. See Don't Overload Generator in Operation section.
2. Replace air filter.
Contact authorized service facility.