Corrective Action - SATA jet 3000 B RP Instrucciones De Servicio

Ocultar thumbs Ver también para jet 3000 B RP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 123
<< Operating Instructions SATAjet 3000 B RP (DIGITAL) >>
EN
Malfunction
Air bubbles appearing
in the gravity flow cup
Spray pattern is too
small, crooked, lop-
sided or splitting
No function of round/
flat spray control - con-
trol knob can still be
turned
Round/flat spray con-
trol cannot be regu-
lated
Spray gun does not
shut-off air
VII.12
Cause
Loose air cap
Gap between air cap
and fluid tip ("air cir-
cuit") is clogged
Nozzle set is clogged
or damaged
Not enough paint ma-
terial in the gravity flow
cup
Defective paint needle
sealing
Clogged air cap drill-
ings
Damaged fluid tip (fluid
tip aperture)
Air distribution ring has
not positioned in cor-
rect location (pin is not
located in the drilling)
or damaged
Control has been
turned too much in
counterclockwise di-
rection; spindle has
loosend inside the
spray gun thread
Clogged air piston seat
or worn air piston.

Corrective Action

Tighten air cap [2-2]
by hand
Clean air circuit, ob-
serve chapter 8
Clean nozzle set,
chapter 8, or replace,
respectively, chapter
9.1
Refill gravity flow cup
[1-6]
Replace the paint nee-
dle sealing, chapter
9.3
Clean air cap, observe
chapter 8
Check if fluid tip is
damaged, replace the
nozzle set, if neces-
sary, chapter 9.1
Replace air distribution
ring making sure it has
been positioned cor-
rectly when inserting it,
chapter 9.2
Remove control with
universal spanner;
rectify or replace com-
pletely, chapter 9.6
Clean air piston seat
and/or replace air pis-
ton, air piston packing,
chapter 9.4

Publicidad

Tabla de contenido
loading

Tabla de contenido