Alliance Laundry Systems JT30XG Manual De Instalación, Operación, Mantenimiento Y Seguridad página 30

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
Solvent gases and vapors from dry
cleaning machines create acids when
drawn through the heater of a drying
tumbler. These acids are corrosive to the
drying tumbler as well as to the laundry
load being dried. Be sure make-up air is
free of solvent gases and vapors.
If the dry cleaning machines are in the
same area as the tumbler, then the
tumbler make-up air must come from a
source free of solvent gases and vapors.
REMOVABLE STRIP OF PANEL IN FRAMING WALL
TO PERMIT REMOVAL OF DRYING TUMBLER
T108IE3A
28
FOR BEST PERFORMANCE
provide an individual exhaust
duct for each drying tumbler.
Do not install a hot water heater
in room containing drying
tumblers. It is better to have
the water heater in a separate
room with a separate air inlet.
T075IE3A
FROM FRAMING WALL
ONE
DRYING
TUMBLER
TWO
DRYING
TUMBLERS
THREE
DRYING
TUMBLERS
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
To reduce the risk of fire and
accumulation of combustible gases, DO
NOT exhaust tumbler air into a window
well, gas vent, chimney or enclosed,
unventilated area such as an attic wall,
ceiling, crawl space under a building, or
concealed space of a building.
W058
ROOF 30" (76.2 cm)
ROOF 30" (76.2 cm)
PARTITION OR
BULKHEAD
Figure 3
WARNING
NOTE: Do not install wire
mesh or screen in this
opening as lint will build up
and prevent proper discharge
of air from drying tumblers.
CEILING
CONSULT YOUR LOCAL BUILDING
CODE FOR REGULATIONS WHICH
MAY ALSO APPLY
NOTE: Inside of duct shall be
smooth. Do not use sheet
metal screws to join sections.
W059
WALL
36 INCHES
(91.4 cm)
RECOMMENDED
SERVICE AREA
24 INCHES
(61.0 cm)
MINIMUM
T108IE3B
M414670