STEAM REQUIREMENTS
For 120 Pound Steam Drying Tumblers Only
NOTE: Sizing of pipe diameters is shown for
steam at rated pressure of 120 psi. Pipe diameter
needs to be increased accordingly if pressure is
less than 125 psi, see Table 5. Piping must also be
sized accordingly for length of runs, and number
of elbows.
= 3/4" DIAMETER PIPE
STEAM
BONNET
SOLENOID
VALVE
(Supplied with
machine)
TUMBLER
MODEL
120CSH
120CSH
120CSH
40
SUPPLY
RETURN
SHUT-OFF
VALVE
VACUUM
BREAKER
CONDENSATE
RETURN LINE
FROM
SUPPLY LINE
STEAM PRESSURE
(PSI)
120 – 125
60 – 120
35 – 60
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
UNION
CHECK
VALVE
TRAP WITH
STRAINER
VACUUM
BREAKER
CHECK
VALVE
Figure 14
MINIMUM PIPE
DIAMETER
1" (2.5 cm)
1" (2.5 cm)
1-1/4" (3.2 cm)
Table 5
12" (30.5 cm)
RISERS
SHUT-OFF
VALVE
BUILT-IN
STEAM TRAP SIZE
(Pounds Condensate/Hour)
345
345
345
T221IE3I
M414670