STEAM REQUIREMENTS
For 170 Pound Steam Drying Tumblers Only
NOTE: Sizing of pipe diameters is shown for
steam at rated pressure of 120 psi. Pipe
diameter needs to be increased accordingly if
pressure is less than 125 psi, see Table 6.
Piping must also be sized accordingly for
length of runs, and number of elbows.
= 3/4" DIAMETER PIPE
= 1" DIAMETER PIPE
STEAM
BONNET
CONDENSATE
RETURN LINE
FROM
SUPPLY LINE
TUMBLER
MODEL
170CSH
170CSH
170CSH
M414670
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
SUPPLY
RETURN
SHUT-OFF
VALVE
SOLENOID VALVE
(Supplied with
machine)
VACUUM
BREAKER
STEAM PRESSURE
(PSI)
110 – 125
60 – 110
35 – 60
UNION
CHECK
VALVE
TRAP WITH
VACUUM
BUILT-IN
BREAKER
STRAINER
CHECK
VALVE
Figure 15
MINIMUM PIPE
DIAMETER
1" (2.5 cm)
1-1/4" (3.2 cm)
1-1/2" (3.8 cm)
Table 6
12" (30.5 cm)
RISERS
SHUT-OFF
VALVE
T220IE3E
STEAM TRAP SIZE
(Pounds Condensate/Hour)
517
517
517
41