Boiler Description; Installation Regulations; Installer Manual-User Manual - Beretta CIAO S 20 C.S.I. Manual De Instalacion Y Uso

Ocultar thumbs Ver también para CIAO S 20 C.S.I.:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
INSTALLER
1 - GENERAL SAFETY DEVICES
Our boilers are built in our plants and checked down to the
smallest detail in order to protect users and fi tters from injury.
After working on the product, qualifi ed personnel must check
the electrical wiring, in particular the stripped part of conduc-
tors, which must not stick out from the terminal board, avoid-
ing possible contact with live parts of such conductor.
This instruction manual, together with the user manual, are
integral parts of the product: make sure that they remain with
the appliance, even if it is transferred to another owner or
user, or moved to another heating system. In case of loss
or damage, please contact your local Technical Assistance
Service for a new copy.
Boiler installation and any other assistance and maintenance
operation must be carried out by qualifi ed personnel accord-
ing to current local and national regulations.
The installer must instruct the user about the operation of the
appliance and about essential safety regulations.
This boiler must only be used for the application it was de-
signed for. The manufacturer declines all contractual and
non-contractual liability for injury to persons or animals or
damage to property deriving from errors made during instal-
lation, adjustment and maintenance and from improper use.
After removing the packaging, make sure the content is in
good conditions and complete. Otherwise, contact the dealer
from who you purchased the appliance.
The safety valve outlet must be connected to a suitable col-
lection and venting system. The manufacturer declines all li-
ability for any damage caused due to any intervention carried
out in the safety valve.
Dispose of all the packaging materials in the suitable contain-
ers at the corresponding collection centres.
Dispose of waste being careful not harm human health and
without employing procedures or methods which may dam-
age the environment.
During installation, inform the user that:
- in the event of water leaks, the water supply must be shut off and
the Technical Assistance Service must be contacted immediately
- the operation pressure of the hydraulic system must be within 1
and 2 bar, and therefore, must no exceed 3 bar.If necessary, reset
the pressure as indicated in the paragraph entitled "Filling the
system"
- if the boiler has not been used for a long time, it is recommended
that the Technical Assistance Service performs, at least, the fol-
lowing operations:
• turn "off" the main switch of the appliance and the general
switch of the system
• close the gas and water taps on both the heating and domes-
tic hot water circuits
• drain the heating and domestic hot water circuits to prevent
freezing
- boiler maintenance must be carried out at least once a year. This
should be booked in advance with the Technical Assistance Ser-
vice.
For safety, always remember that:
The boiler should not be used by children or unassisted disabled
people.
It is dangerous to activate electrical devices or appliances,
such as switches, home appliances, etc., if you smell gas or
fumes. In the event of gas leaks, ventilate the room opening
In some parts of the manual, some symbols are used:
WARNING = for actions requiring special care and adequate
preparation
FORBIDDEN = for actions THAT MUST NOT be performed
doors and windows; close the gas general tap; contact the
qualifi ed personnel from the Technical Assistance Service im-
mediately
Do not touch the boiler while barefoot or if parts of your body
are wet or damp
Before cleaning operations, disconnect the boiler from the
main power supply by turning "OFF" the two position system
switch and the main control panel switch
Do not modify safety and adjustment devices without the
manufacturer's permission and relative instructions
Do not pull, disconnect or twist the electric cables coming
out of the boiler even when it is disconnected from the main
power supply
Avoid covering or reducing the size of ventilation openings of
the installation room
Do not leave infl ammable containers and substances in the
installation room
Keep packaging materials out of reach of children.

2 - BOILER DESCRIPTION

Ciao S C.S.I. is a C-type wall-mounted boiler for heating and pro-
duction of domestic hot water: according to the fl ue gas outlet de-
vice, the boiler is classifi ed in categories B22P, B52P, C12, C22,
C32, C42, C52, C62, C82, C92, C12x, C32x, C42x, C52x, C62x,
C82x, C92x.
Ciao S R.S.I. is a Type C wall-mounted boiler that can function in
various mode:
MODE A
Heating only without any external storage tank connected.
The boiler does not supply domestic hot water.
MODE B
Heating only with a thermostatically controlled external storage
tank connected: in this condition, with every heat request from the
storage tank thermostat, the boiler supplies hot water for the prepa-
ration of the domestic hot water.
MODE C
Heating only, with the connection of an external storage tank (ac-
cessory kit available upon request) (managed by a temperature
probe) for preparing domestic hot water. When connecting the stor-
age tank not supplied by us, make sure that the NTC probe has the
following characteristics: 10 kOhm at 25°C, B 3435 ±1%
In confi guration B22P and B52P (when installed indoors), the ap-
pliance cannot be installed in bedrooms, bathrooms, showers or
where there are open fi replaces without a proper air fl ow. The room
where the boiler is installed must have proper ventilation.
In confi guration C, the appliance can be installed in any type of
room and there are no limitations due to ventilation conditions or
room volume.

3 - INSTALLATION REGULATIONS

3.1 - Installation regulations
Installation must be carried out by qualifi ed personnel.
Always comply with national and local regulations.
POSITION
Ciao S can be installed indoors (fi g. 2).
The boiler has protection that guarantees correct operation with a
temperature range from 0°C to 60°C.
To take advantage of protections, the appliance must be able to
start up, since any lockout condition (for example, absence of gas or
electrical supply, or safety intervention) deactivates the protections.
MINIMUM DISTANCES
In order to have access to the boiler to perform regular maintenance
operations, respect the minimum spaces foreseen for installation
(fi g. 3).
For correct appliance positioning:
CIAO S C.S.I. - CIAO S R.S.I.
3

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ciao 24 c.s.i.Ciao s 24 r.s.i

Tabla de contenido