4. Determine roof structure mounting points
The angle irons should be aligned with the outermost holes of the upper mount.
Determine the mounting points in the roof structure for the angle irons. Consult the appropriate diagram below
for distances between the angle irons. Dashed lines represent angle irons.
10-7/8" (276 mm)
Ø9/16''
(14 mm)
5-1/2"
(140 mm)
Small Upper Mount (Standard)
13-3/4'' x 9-1/2" (349 x 241 mm)
Direct Mount
Ø9/16'' (14 mm)
5-1/2"
(140 mm)
WWW.BIGASSFANS.COM
Large Upper Mount (Optional)
18-1/2'' x 9-1/2" (470 x 241 mm)
5-1/2" (140 mm)
Top of Main Fan Unit
© 2018 DELTA T LLC
ALL RIGHTS RESERVED.
15-5/8" (397 mm)