EdilKamin TINY Instalación Uso Y Mantenimiento página 56

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 86
TROUBLESHOOTING TIPS FOR KELLY
5) H5 Power failure stoppage (not a defect of the stove).
Turns off due to lack of electricity
Check electricity connection and drops in voltage.
6) H6 Thermocouple failure (intervenes if the thermo coupling has failed or is disconnected).
Turns off due to thermo coupling failed or disconnected
Check connection of thermo coupling to board: check function in cold test.
7) H7 Excessive smoke temperature turns off due to exceeding maximum smoke temperature.
Excessive smoke temperature may depend on: pellet type, anomaly in smoke extraction, smoke channel blocked,
incorrect installation, gear motor 'drift'
8) Batt. 1 - Batt. 2
The heating stove will not stop, but this message appears on the display. The buffer battery on the pcb must be replaced.
Display-control panel off:
• make sure the power cord is connected check the fuse (on the power socket)
Remote control (optional) not working:
• closer to the receiver of the stove
• check the battery and if necessary, replace it
Outlet air not hot:
• clean heat exchanger from inside the firebox.
During ignition, the differential switch trips (DEALER):
• check moisture content of ignition resistance
Does not ignite:
• clean combustion chamber.
The message is displayed until the 0/1 key on the panel is pressed.
Do not restart the stove until the problem has been looked into and the cause removed.
It is important to tell the Dealer exactly what the panel signals.
56

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kelly

Tabla de contenido