Ingecon Sun 3Play Tl (28~33 Kw) - Ingeteam INGECON SUN 10TL Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 147
Ingeteam
Version S+
A
B
A.
DC isolating switch.
B.
SD card reader.
C.
M25 Packing glands for DC wiring. Accepted
cable diameter range 7 ~ 17 mm, using the
included reducer.
D.
M50 Packing glands for AC wiring. Accepted
cable diameter range 16 ~ 35 mm.
2.9.2. INGECON SUN 3Play TL (28~33 kW)
Versions P and P+
A
B
A.
DC isolating switch.
B.
SD card reader.
C.
DC+ quick connectors.
D.
DC- quick connectors.
E.
M50 Packing glands for AC wiring. Accepted
cable diameter range 16 ~ 35 mm.
92
C
C
D
E.
Holes for M16 packing glands for accessories.
Accepted cable diameter range 4.5 ~ 10 mm.
F.
Hole for M20 cable glands for accessory for
communication via Ethernet. Accepted cable
diameter range 6 ~ 13 mm.
C
D
E
F.
Holes for M16 packing glands for accessories.
Accepted cable diameter range 4.5 ~ 10 mm.
G.
Hole for M20 cable glands for accessory for
communication via Ethernet. Accepted cable
diameter range 6 ~ 13 mm.
ABO2011IQM01_A - Installation and Operation Manual
Unit description
E
E
F
E
F
F
G
F