Three-Phase Motor Specifications - Franklin Electric SubDrive Solar Manual De Instrucciones

Ocultar thumbs Ver también para SubDrive Solar:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Alternate AC Source Line Reactor Specifications
A single-phase line reactor is recommended when using an alternate AC source, located
between the AC source and the controller. Without a line reactor, the drive can experience
excessive heating and will reduce performance or stop to protect itself.
• Minimum 0.4 mH inductance, rating of 25 ampere rms current, continuous, for 2.2 kW
• Minimum 0.4 mH inductance, rating of 15 ampere rms current, continuous, for 1.1 kW
• Minimum 0.4 mH inductance, rating of 10 ampere rms current, continuous, for 0.55 kW
Line reactors are typically available as three-phase line reactors. Follow the manufacturer's
instructions for use in single-phase application. The reactors can be mounted at the alternate AC
source, using the proper enclosure rating determined to be adequate.

Three-Phase Motor Specifications

MOTOR
MODEL
HP
2349029204
0.75
2345049203
1.5
2343062604
3
Maximum Motor Cable Length (in feet)
Drive Model
SD Solar 0.55 KW N3
SD Solar 1.1 KW N3
SD Solar 2.2 KW N3
Maximum Motor Cable Length (in meters)
Drive Model
SD Solar 0.55 KW N3
SD Solar 1.1 KW N3
SD Solar 2.2 KW N3
* Maximum cable length from the drive to the motor is 1000 ft (305 m). External filtering is required for motor
cable lengths exceeding this maximum distance or nuisance tripping might occur.
RATING
KW
VOLTS
HZ
S.F.
0.55
100
60
1.5
1.1
200
60
1.3
2.2
200
60
1.15
Table 4: Motor Specification Data
AWG Copper Wire Size, (75 °C Insulation)
Motor
14
12
HP
0.75
130
220
1.5
310
500
3.0
180
290
Square Millimeter Copper Wire Size, (75 °C Insulation)
Motor
1.5
2.5
KW
0.55
20
40
1.1
70
120
2.2
30
60
Table 5: Wire Sizing Charts
MAXIMUM
FULL LOAD
LOAD
AMPS
WATTS AMPS WATTS
6.9
830
8.6
5.8
1460
6.8
10.9
2920
12.5
10
8
6
340
530
830
790
1000
470
740
1000
4
6
10
70
110
190
190
290
305
100
160
260
LINE TO LINE
KVA
RESISTANCE
CODE
OHMS
1185
1.1 – 1.4
1890
2.5 – 3.0
3360
1.3 – 1.7
4
16
300
305
N
K
K
25

Publicidad

Tabla de contenido
loading