9 Appendix
9.1 Technical Data
Supply voltage
Motor output
Maximum power consumption
Duty cycle
Type of protection
ISO Class
Permitted ambient temperature
Fan capacity, max.
Device capacity, max.
Vacuum, max.
Minimum extraction performance (flow
monitoring trigger threshold)
Exhaust arm
Filter surface area
Welding fume separation class as per EN
ISO 15012-1
Sound pressure level at 1m distance as
per DIN EN ISO 3744
Width
Depth
Height
Weight
Art. No.: 150 2120
Technical changes and errors excepted.
02/2015
KEMPER SmartMaster Operating Instructions - EN
Single phase AC, see Identification
Plate
1.1 kW
See Identification Plate
100%
IP 42
F
-10 / +40°C
1,600 m³/h
1,300 m²/ h without exhaust arm
950 m³ / h, with exhaust arm
1,500 Pa
400 m³/h
Nom. diam. 150, 2 m or 3 m
Prefilter cassette 2.2 m
Main filter 13 m
W3
72 dB(A)
580 mm
580 mm
900 mm
72 kg without exhaust arm
81 kg with 2 m exhaust arm
- 59 -