Error messages
•
When the "ERR" message is shown on the display, an error has occurred. The following errors are
possible:
ERR no01 EEPROM has been incorrectly programmed and an internal data error has occurred.
ERR no02 Only for testing purposes.
ERR no03 The frequency that you wish to program is higher than the broadcaster's switching
bandwidth. Use a receiver with the required critical band. (At this time the microphone
still works and the frequency remains unchanged. To delete the "ERR" message, turn
your device off and on again.)
ERR no04 The frequency that you wish to program is lower than the broadcaster's switching band-
width. Use a receiver with the required critical band. (At this time the microphone still
works and the frequency remains unchanged. To delete the "ERR" message, turn your
device off and on again.)
"Group" and "channel" display
•
If both the group and channel are displayed, you are using one of the receiver's pre-programmed
frequencies.
"Channel" display
•
If only the channel is displayed, you are using a frequency that has not been pre-programmed.
Battery status display
•
The remaining operating time of the batteries is shown on the display. When the battery display
shows a capacity of 10%, the batteries should be changed or, if using rechargeable batteries, should
be recharged. Should you continue to use the transmitter, it will turn off automatically after a certain
period of time to avoid total discharge (especially when using rechargeable batteries). The display
shows the message "OFF".
Display upon turning off
•
When you turn the transmitter off, the display will show the "OFF" message.
•
To turn the transmitter off, press and hold the on/off button for approx. 2 seconds.
Transmitter battery display
63