Flow Sensor
To attach a flow sensor, connect the flow
sensor's red wire to the F terminal on
the base module, and connect the flow
sensor's black wire to the terminal marked
with a dash ( - ), just below the F terminal.
ET Water controllers will only work with
Data Industrial flow sensors or their
equivalent. (Note: The flow sensing
feature carries a yearly activation fee.
Call customer support to activate the flow
sensor feature and to receive directions
on how to set up the flow sensor in your
ET Water Manager account.)
Rain Sensor
IMPORTANT: Use the instructions below to install and activate your rain sensor even if
you have different instructions that came with your sensor.
Attach one of the rain sensor wires to the R
terminal on the base module, and connect
the other rain sensor wire to the terminal
marked with a dash ( - ), just below the
R terminal. Do not install the rain sensor
such that the common wire is interrupted.
Once the controller is powered on, press
the SENSOR SETUP button, then press
the UP arrow button to activate the rain
switch.