24 | KTS ��� | Operation
5.4
Standby mode setting
In the menu "Programs » Control Panel » Energy
Options", you can specify the parameters, which enable
the KTS 670 to deliberately move into standby mode
in power pack or battery operation, and switch off
the monitor or the hard disk. Select the menu option
"Power Schemes" and set the desired parameters.
The figure shows the default factory settings
!
Do not change the settings in the other menu options.
|
1 689 989 017
2008-07-04
5.5
Operation
i
Further information is available in the online help.
5.5.1
Multimeter and oscilloscope
Danger from high voltage!
If measurements are taken without a
ground lead, potentially deadly voltages
can build up.
¶
If no diagnostic cable is connected, and
before making U, R or I measurements,
ensure that the KTS 670 (Figure. 1,
Item 2) is grounded by connecting the
accompanying ground lead to the vehicle
ground!
¶
Connect the ground lead as closely as
possible to the measurement object!
¶
Use the KTS 670 only on the vehicle and
not for measurements on voltages > 60
Volt! Do not make any measurements on
ignition systems!
¶
Only use the accompanying measuring
cables with touch protection!
¶
Always plug the measuring cables into
the KTS 670 first and then into the
vehicle!
¶
Unshielded measuring cables must not
be placed close to strong sources of dis-
turbance, for example ignition cables!
¶
In the case of highly resistive sensor
signals with low level, use the shielded
measuring cable 1 684 465 490 (special
accessories).
For the KTS 670, a 2-channel multimeter and a 2-chan-
nel oscilloscope are available to you.
If the KTS 670 is used to make voltage measurements
with the multimeter or oscilloscope via measuring chan-
nel CH2, the power supply will be switched off via the
vehicle, as the measuring channel CH2 is not at zero po-
tential, and it can therefore lead to faulty measurements.
i
When reading out vehicle data in the control unit
diagnostics mode, the 1-channel oscilloscope has a
limited functionality (scan rate 50 kHz instead of 100
kHz) and the 2-channel oscilloscope can not be used.