11. Malfunctions
The malfunctions described below may only be remedied by trained per-
sonnel.
If it is not possible to remedy a malfunction with the described corrective
actions, send the spray gun to the SATA customer service department
(address see chapter 16).
Malfunction
Jerky spray fan pat-
tern (wobbling / splut-
tering) or air bubbles
in the gravity flow cup.
Air bubbles in gravity
flow cup.
Cause
Fluid tip not tightened. Tighten fluid tip with
Air distribution ring
damaged or clogged.
Loose air cap.
Gap between air cap
and fluid tip (air circuit)
is clogged.
Nozzle set is soiled.
Damaged nozzle set.
Not enough material in
gravity flow cup.
Defective paint needle
seal.
Corrective Action
universal spanner.
Replace air distribution
ring (see chapter 9.2).
Tighten the air cap
hand-tight.
Clean air circuit. Heed
cleaning instructions
(see chapter 10).
Clean nozzle set. Heed
cleaning instructions
(see chapter 10).
Replace nozzle set (see
chapter 9.1).
Fill gravity flow cup (see
chapter 8.2).
Replace paint needle
seal (see chapter 9.3).