Disposal; After Sale Service; Accessories - SATA SATAjet 100 B F RP Instrucciones De Servicio

Ocultar thumbs Ver también para SATAjet 100 B F RP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 147
Operating Instructions SATAjet 100 B F (RP / HVLP), B P
Malfunction
Corrosion on air
cap thread, material
passages (cup con-
nection) or spray gun
body.
Material leaks from
behind the paint nee-
dle seal.
Spray gun drips at flu-
id tip ("fluid tip cone").

12. Disposal

Dispose of the completely emptied spray gun as a recyclable material.
To avoid damage to the environment, dispose of the spray material and
release agent separately from the spray gun in an appropriate manner.
Comply with local regulations!

13. After Sale Service

Please refer to your local SATA dealer for accessories, spare parts and
technical support.

14. Accessories

Art. No.
Description
6981
Quick coupling nipple G1/4 IG
27771
Air micrometer 0 – 845 with pressure gauge
64030
SATA cleaning set
53090
Air hose
48173
High performance grease
Cause
Cleaning solution (wa-
tery) remains in the
gun for too long.
Unsuitable cleaning
solutions used.
Paint needle seal de-
fective or missing.
Paint needle dam-
aged.
Paint needle clogged.
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Corrective Action
Have gun body re-
placed. Heed cleaning
instructions (see chap-
ter 10).
Replace paint needle
seal (see chapter 9.3).
Replace nozzle set (see
chapter 9.1).
Clean paint needle.
Heed cleaning instruc-
tions (see chapter 10).
Clean fluid tip and paint
needle. Heed cleaning
instructions (see chap-
ter 10).
Replace nozzle set (see
chapter 9.1).
Num-
ber
5 ea.
1 ea.
1 set
1 ea.
1 ea.
EN
143

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Satajet 100 b f hvlp satajet 100 b p

Tabla de contenido