Emptying The Collector Bin; To Replace The Antistatic Plastic Bag; Replacing The Main Filter, Control Filter And Filter Bags - Nederman E-PAK 150 DX Manual De Instrucciones

Ocultar thumbs Ver también para E-PAK 150 DX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 115
EN
E-PAK 150 DX/300 DX/500 DX
10.3
10.4
42
Clean the area around the unit and all areas where the collected material is
stored to ensure that there are no dust deposits.
Ensure that there is not any combustible material in the risk area.
Check that all signs/markings regarding safe operation are in place and that the
personnel knows about them.

Emptying the collector bin

WARNING!
Risk of personal injuries.
Ensure that there is no vacuum in the dust separator before removing the
collector bin.
WARNING!
Risk of personal injuries.
Crush hazard. Pay attention when lowering and refitting the collector bin. Use
proper protective equipment.
WARNING!
Risk of personal injuries.
Wear a protective mask.
The antistatic plastic bag is to be replaced when filled up to 2/3.
NOTE!
Use Nederman antistatic plastic bags only.

To replace the antistatic plastic bag:

1.
Check that the risk area is clear.
2.
Ensure that there is no vacuum in the dust separator.
3.
Remove the collector bin.
4.
Seal and remove the antistatic plastic bag. Use a cable tie or equivalent,
see Figure 13.
5.
Fit a new antistatic plastic bag in the collector bin.
6.
Refit the collector bin onto the dust separator.
7.
Check that the pressure equalizer hose is attached to the collector bin, see
Figure 14.
8.
Check that the collector bin seals properly once vacuum is re-applied to
the dust separator.
CAUTION!
Risk of equipment damage
Never operate the unit without a Nederman antistatic plastic bag.
Replacing the main filter, control filter and filter bags
WARNING!
Risk of electric shock.
Always disconnect the supply voltage with the maintenance switch before any
service, whether mechanical or electrical. Always lock the maintenance switch
in the off position.
WARNING!
Risk of personal injuries.
Ensure that there is no vacuum present in the system during service.
WARNING!
Risk of personal injuries.
Always disconnect the compressed air supply before any service.