5. Press
to inflate the tyre. The tyre will expand, and the beads will seat.
If necessary:
6. Continue inflating up to the maximum value of
3.5 bar to position the tyre correctly on the rim.
Avoid distractions during this operation, and con-
tinually check tyre pressure on the air pressure
gauge (17, Fig. 10) to prevent excessive inflation.
Inflating tubeless tyres requires a higher air flow-
rate to allow the beads to bypass the rim HUMPS
- see types of rim profiles for mounting without a
camera in Fig. 28c.
7. From the position of the centring ridges check that the beads are properly positioned
on the rim; otherwise, deflate the tyre, break the beads as described in the relevant sec-
tion, lubricate and turn the tyre on the rim. Repeat the mounting operation described
previously and check again.
8. Replace the internal mechanism of the valve.
9. Bring the pressure to the operating value by pressing the Inflation push-button (1,
Fig. 10a).
10. Fit the cap to the valve.
6.9.c. SPECIAL PROCEDURE (TI VERSION ONLY)
Before carrying out the operations described below, always make sure that there is no
dirt, dust or other impurities on the jaws near the air outlet holes.
If, during inflation, the tyre does not seat on the
rim because of the excessive gap between tyre/
rim, it is possible to use an air-pressure airblast
through jaws on TI accessory.
Verify that both upper and lower tyre beads and
rim bead seat have been properly lubri- cated with
an approved mounting paste.
1. Make sure the wheel on which the tyre is fitted
is securely clamped on the turntable by the
centering handle (Fig. 29).
AQUILA ALLIANCE User Manual
"double HUMP" (H2)
WARNING
"HUMP" (H)
28c
29
115