FRESH AIR DUCTS

For correct operation, air must be allowed to recirculate inside the structure that covers the insert in order to prevent the appliance from
overheating.
To guarantee this, just realise one or more openings in the lower and upper part of the covering.
The following measurements must be respected:
Lower part (cold air inlet) with total minimum surface 550 cm².
Upper part (hot air outlet) with total minimum surface 550 cm².
IMPORTANT: ALL OPENINGS MADE FOR PROPER AIR RECIRCULATION MUST BE MADE INACCESSIBLE BY MEANS
OF APPROPRIATE PROTECTIVE GRILLES OR MESHES, ENSURING THE MINIMUM PASSAGE OF AIR REQUIRED.
THE PIPE FOR FUMES OUTLET MUST ALWAYS MAINTAIN A MINIMUM DISTANCE OF 50 MM FROM INFLAMMABLE PARTS.
Reference A
Š Convection hot air 550 cm²: The heat accumulated inside the covering must
A
be vented to prevent excessive overheating of the insert.
Reference B
Š Forced ventilation:
The tangential fan delivers the heat developed by the insert into the
environment.
B
Reference C
Š Air inlet from environment of 550 cm²:
In order to allow the air to re-circulate, an inlet point must be envisioned
that is preferably positioned in the lower part of the structure in order to
promote convection. The air must be removed from the machine work
C
environment.