SETTINGS
DATE/TIME
LANGUAGE
SET DEGREES
DISPLAY
The "DISPLAY" menu allows:
Regulation of DISPLAY contrast
Activation/Deactivation of backlight.
Enabling/disabling of acoustic signal.
Setting of the timer to turn o the Display backlight.
Setting of the timer to turn o the Display (sleep mode).
To set: OK > SETTINGS > DISPLAY.
STAND BY
The Stby function is used in the event the stove needs to turno immediately or modulation via
additional thermostat. STBY will be seen on the display, which indicates the function is active.
To set: OK > SETTINGS> STAND BY.
THIS FUNCTION IS NOT RECOMMENDED FOR ENVIRONMENTS WITH SCARCE THERMAL INSULATION OR WHERE
THERE MAY BE SHARP FLUCTUATIONS IN TEMPERATURE: DOORS OR WINDOWS CONSTANTLY OPENED.
FIRST LOAD
This function allows to ll the auger, facilitating the phases of the rst start-up of the stove, or in the
event that the pellet tank is empty.
With the stove cold and "OFF", make sure the pellet has been introduced inside the tank and activate
the FIRST LOAD function, con rming with OK.
To interrupt the loading in continuous, simply press the key
To set: OK > SETTINGS > FIRST LOAD.
REMEMBER ALWAYS TO COMPLETELY EMPTY THE BURN POT BEFORE IGNITION AND THAT THE HOLES IN THE BURN POT
OUTLET AIR
This function allows any air in the stove to be discharged. By activating the pump function, it will be
powered alternatively with 30 second work phases and 30" stop for 15 minutes. With the stove cold
and in "OFF", activate the OUTLET AIR function, con rming with OK. To interrupt, remove the power
supply.
To set: OK > SETTINGS > OUTLET AIR.
CLEANING THE EXCHANGER
This function allows to set the time range within which the automatic cleaning of the springs is active.
To set: OK > SETTINGS > EXCHANGER CLEANING
68
ARE ALL FREE. NEVER EMPTY THE BURN POT INSIDE THE PELLET HOPPER, FIRE RISK!
SEE CHAPTER: COMMISSIONING SETTINGS.
for 3 seconds.
OK
ENGLISH