RESET
Allows the user to reset all modi able values to the default values.
To set: OK > SETTINGS > RESET.
ADDITIONAL FUNCTIONS
AUX
If conveyor accessories of the manufacturer are used , the connection must be made by a quali ed technician.
Contact the dealer for further details
LCD HANDHELD REMOTE ROOM PROBE CALIBRATION
This mode allows calibration of the room temperature detected by the LCD handheld remote (with ventilation active only). For correct
calibration, it is recommended to position the LCD handheld remote in a room with constant temperature and wait for at least two hours.
Below nd the calibration procedure:
Access the menu and reach "TECH MENU".
Set the access key "F4". - "ADJ REMOTE PROBE"
Using the keys
or
Save and exit with the key
ADDITIONAL THERMOSTAT
N.B. : Installation must be performed by an authorised technician
There is a possibility to thermostat a room adjacent to the room where the stove has been placed; simply connect a thermostat following the
procedure described in the following section (it is advisable to place the optional mechanical thermostat at a heigh from the ground equal to
1.50m). Stove operation with external thermostat connected in the clamp TA can be di erent on the basis of activation or deactivation of the
STAND BY function.
By default, the clamp TA exits jumpered, therefore it always has closed contact (on request).
ADDITIONAL THERMOSTAT FUNCTIONING WITH STAND BY ACTIVE
When the function is activated, STBY will be shown on the display. When the contact or external thermostat is not satis ed (open contact
=temperature reached), the stove will switch o . As soon as the contact or external thermostat switches to the "not satis ed" status (closed
contact / temperature to be reached) it will re-ignite.
Nota bene: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If stove
is in H OFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL THERMOSTAT OPERATION WITH STAND BY DEACTIVATED
When the contact or external thermostat is satis ed (open contact / temperature reached), the stove will go to minimum. As soon as the contact
or external thermostat switches to the "not satis ed" status (closed contact / temperature to be reached) it will start to work again at the pre-set
power.
Nota bene: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If stove
is in H OFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL THERMOSTAT INSTALLATION
Remove the plug from the socket.
Connect the two cables of the thermostat
on the terminal (TA) behind the machine,
and secure them to the cable holder (A).
adjust the desired ambient calibration.
.
OK
OK
ENGLISH
A
TA
69