2.3.1 ASSEMBLY OF THE ACCESSORIES

The probe-holder is installed on a D50 or D63 diameter tube on which a 24 mm diameter hole has been
carried out;
Check the direction of the flow in the tube to insert the injection tube correctly;
The probe-holder must be positioned vertically +- 45°
Performing a D24 mm hole
Conduct a 5 mm pre-hole at the centre of the upper part of the tube;
Expand the hole with the 24mm drill bit supplied in the installation kit, until you introduce the whole
drill bit in the tube;
Deburr the hole by removing the PVC residues;
Installing the probe-holder:
Insert the O-ring on the small injection tube;
Insert the small injection tube on the tube by following the direction of the flow, as indicated by the arrow on
the label;
Position the O-ring in place and hold it there. Apply the upper part of the probe-holder on the pool tube;
Insert the two screws (if it is a DN63 tube use the two spacers between the upper probe-holder and the
lower collar). Apply the lower part of the probe-holder on the tube and tighten the nuts on the screws;
Screw the clamping screws evenly to achieve proper fastening. Do not tighten a screw fully home
when the other one is still unscrewed.
Installing the short electrode
6. Remove the cap from the electrode. (Carefully store away the cap, you will need it during maintenance or
when the equipment is not used during winter. In this case, it must placed back on the electrode after filling
it up to ¾ with water);
7. Insert the two O-rings and slide them until they reach the lower part of the electrode's head;
8. Pass the electrode's cable on the slot located on the ring nut;
9. Now go ahead with the calibration of the probe described in chapter 3.3.3 and then proceed with section 5;
10. Insert the electrode in the probe-holder without forcing it in until the O-ring positions itself between the
lower part of the electrode head and the seat on the probe-holder. Then tighten the ring nut manually;
Refer to Fig. 3
ADSP7000407
Fig. 2- Probe-holder Assembly
rev. 1.2
INSTRUCTION AND MAINTENANCE MANUAL
27/03/2015
ENGLISH
45/313