Electrical Connections - BSVILLAGE PISCINE Simpool Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 119
Simpool pH model
Programmable digital peristaltic pump
Installing a long electrode (120 mm)
It is possible to use a standard electrode (12x120 mm). In this case it is necessary to use all the parts supplied;
Insert the following in sequence on the body of the probe: the ring nut and then alternate a
spacer and an O-ring as shown in Fig. 4
Gently insert the electrode on the probe-holder by carrying out small clockwise and
anticlockwise rotations to make the O-rings move down. When all the components are in
place, tighten the ring nut manually.
Never bend the electrode, which would otherwise be irreparably damaged. The
internal part of the electrode is very fragile!

2.4 ELECTRICAL CONNECTIONS

Before performing any intervention on the pump, disconnect the power supply voltage of the
machine!
ADSP7000407
Fig. 3- Mounting the probe in the probe-holder
Fig. 5- View from below
rev. 1.2
INSTRUCTION AND MAINTENANCE MANUAL
Fig. 4- Long pH Electrode
27/03/2015
ENGLISH
46/313

Publicidad

Tabla de contenido
loading

Tabla de contenido