Alarms; Maintenance Alarm; Level Alarm - BSVILLAGE PISCINE Simpool Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 119
Simpool pH model
Programmable digital peristaltic pump
 Choose if you want to modify the OFA alarm's time frame from the User Menu, OnA: to enter and exit the
submenu use Enter, to scroll through "YES/no" use the ▲ and ▼ keys;
 Enable the b.En buzzer when an alarm is activated: to enter and exit the submenu use Enter, to scroll
through "YES/no" use the ▲ and ▼ keys;
To go back to the Programming Menu, to the Opt entry, just press Enter for 3 seconds from any entry of the Menu.

4.0 ALARMS

The entry that reports the active alarm with the top priority is only displayed alternated with the entries of the Initial
Menu, while there will be an audio signal (if the buzzer is enabled) and a flashing red LED associated with the
status of the Alarm both on the Initial Menu and the User Menu.

4.1 MAINTENANCE ALARM

The maintenance alarm is activated when the pump has been running for longer than the time set in the relative
O.F.d submenu (see Settings Menu).
If you set 0.00 (h.mm) as a time value for the maintenance alarm, it will be disabled.
This is reported by the pump as follows:
Audio signal via the buzzer (if there is one on the pump) if enabled (see b.En on the "Settings Menu") with a
frequency of 1 second on and 1 second off;
flashing red LED;
"OFd" flashing on the display;
In this alarm status the motor is stationary. To disable the alarm, you need to go to the P.d.t entry (pump operating
time) in the Statistics Menu and reset the value.
4.2 LEVEL ALARM (only for the model with the level probe)
A level probe can be connected to the pump to report the end of the product, which is indicated by the pump in the
following way:
Audio signal via the buzzer (if there is one on the pump) and if enabled (see b.En on the "Settings Menu")
with a frequency of 1 second on and 1 second off;
flashing red LED;
"uLo" flashing on the display;
The inlet has a 3-second recognition filter to identify false contacts and unwanted level alarm signals.
This alarm may or may not imply the pump will stop, depending on the option chosen in the "P.St" submenu
(Settings Menu: P.St=YES the pump is stopped; P.St =no the pump keeps on dosing).
The alarm is automatically reset when the level of the chemical product to be dosed is restored.
In priming mode, the level alarm is not indicated.
ADSP7000407
Fig. 19 - Settings Menu
rev. 1.2
INSTRUCTION AND MAINTENANCE MANUAL
27/03/2015
ENGLISH
59/313

Publicidad

Tabla de contenido
loading

Tabla de contenido