REPLACING THE CENTRE
BRUSH
This machine features a system for
automatically adjusting the pressure exerted
and compensating for the central brush wear.
The need to replace the centre brush is
indicated by the BRUSH WORN code on the
display.
To replace the centre brush, proceed as
follows:
•
Unscrew the knob and open the
23).
•
Unscrew and remove the three
•
Remove the cover of the brush
compartment.
•
•
Remove the adapter from the core
new brush, taking care to keep the
bristles aligned in the same direction
•
Fit the new brush and make sure
that the adapter is inserted on the
drive hub.
•
Replace the brush compartment
cover, following the dismantling
operations in reverse order.
BATTERY MAINTENANCE
AND CHARGING
•
every 30 hours for the battery
version
•
every week for the combustion
engine version.
The battery compartment is located under the
operator's seat.
The battery is a sealed unit and guaranteed
safe under normal circumstances; in the
following precautions:
•
Contact with the skin can cause irritation;
wash with soap and water.
•
Inhalation of vapours can cause irritation
to the airways; stay out in the open air
and consult a doctor.
•
Contact with the eyes can cause irritation;
thoroughly for at least 15 minutes, and
consult a doctor.
When necessary, recharge the batteries
according to the following instructions:
EN
17