13. Fluorescence observation procedures (B-383FL)
Set the power supply switch to "I" (ON) and
wait for the arc to stabilize (5 or 10 minutes).
Place a specimen on the stage.
Insert in the light path the filtercube
suitable for the specimen
Insert the objective into the light path
and focus the specimen.
Adjust until you obtain a bright and even field of view
Insert the shutter when the microscope is
14. Fluorescence observation procedures (B-383LD1/LD2)
Turn on the microscope using the main switch.
Place a specimen on the stage.
Insert in the light path the filtercube
suitable for the specimen
Insert the objective into the light path
and focus the specimen.
Insert the shutter when the microscope
not used for a short time
Begin observation
is not used for a short time
Begin observation
(Used commands)
Fluorescence power supply
Slide holder
X/Y movement knobs
Fluorescence filter slider
Shutter
Nosepiece
Fine and coarse focus knobs
Lamp housing focussing and
centering screws
Shutter
(Used commands)
Main switch
Slide holder
X/Y movement knobs
Fluorescence filter slider
Nosepiece
Fine and coarse focus knobs
Shutter