Ingeteam
6.
From the left-hand panel, add the inverter assigning it to the modbus 1 node.
11.7. Changing the IP settings of a Wi-Fi network
When it connects to an existing Wi-Fi network the inverter will obtain its IP address dynamically (DHCP). If it
connects to a network without DHCP server or if you wish to set up the inverter with a static IP address, follow
these steps:
1.
Open the web application from the device's browser.
2.
Open Comms in the top menu.
3.
Select Wi-Fi in the left panel.
4.
Select the Change option in the Primary field.
5.
In the IP Mode field select the Fixed or DHCP option.
6.
If you have selected Fixed, complete the required data (IP address, IP mask and IP gateway).
INFO
To verify that the gateway and network mask are correct, access the network settings properties of a device that
is on the same network or request it from the network administrator.
7.
Finally, click on Send.
A window will appear with the data of the new IP address setup.
11.8. Changing the IP settings of an Ethernet network
When it connects to an existing Ethernet network the inverter will obtain its IP address dynamically (DHCP). If
it connects to a network without DHCP server or if you wish to set up the inverter with a static IP address, follow
these steps:
1.
Open the web application from the device's browser.
2.
Open Comms in the top menu.
3.
Select Ethernet in the left panel.
4.
Select the Change option in the Primary field.
5.
In the IP Mode field select the Fixed or DHCP option.
6.
If you have selected Fixed, complete the required data (IP address, IP mask and IP gateway).
INFO
To verify that the gateway and network mask are correct, access the network settings properties of a device that
is on the same network or request it from the network administrator.
7.
Finally, click on Send.
A window will appear with the data of the new IP address setup.
11.9. Configuring voltage-free relays and digital inputs
Carry out the following procedure to configure the voltage-free relays and the digital inputs.
1.
Open the web application from the device's browser.
2.
To perform this configuration you must log in as an installer. To do this, click on the user icon and enter
the password ingeconsuninstaller
3.
Go to Config > Digital output/input.
4.
Select the desired configuration and click on Write.