Promax PROLINK-4/4C Premium Manual De Instrucciones página 225

Medidor de nivel tv digital & sat avanzado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USER'S MANUAL. PROLINK-4/4C
To define the DiSEqC commands sequence press key
until cursor is positioned on one line of the commands sequence (the line will blink). If
cursor has been placed on the first empty line, Sat A/B command will appear (first
DiSEqC command of table 6). To select a different command turn the rotary selector
until the desired command appears and then press it.
Some DiSEqC commands need to define an associated parameter (i.e. On/Off, a
numerical value, A/B...), when any of these commands is selected first option for the
associated parameter appears automatically at its right, to change it turn the rotary
selector and to validate it press the rotary selector (see DiSEqC commands table).
Once the DiSEqC command is defined, the cursor will pass to the following line, if
you want to define a new command proceed as for the first one, if you do not want to
add any command press key
After the commands sequence is created it is possible to modify it. To modify the
sequence press key
command you want to make the change and then press the rotary selector [4]: Insert
function will appear on the screen, by turning the rotary selector it is possible to select
Delete and Edit functions. Once the desired function appears on the screen (Insert,
Delete or Edit) press the rotary selector. If you select Delete function the command will
be removed from the sequence, if you select Insert or Edit functions, you must define
the new command as previously described.
Once commands sequence is defined, to send it to the peripherals press key
[31] repeatedly until you have selected the Send function and then press the
rotary selector [4]. At the same time as DiSEqC commands are sent these appear on
the lower side of the monitor. If Send function does not appear on the monitor, place the
cursor over the Clear function and turn the rotary selector.
It is possible to delete the whole of the commands sequence, to do this press key
[31] repeatedly until you have selected the Clear field and then press the rotary
selector [4]. If Clear function does not appear on the monitor, place the cursor over the
Send function and turn the rotary selector.
To exit DiSEqC function place the cursor over the Exit field and then press the
rotary selector [4].
REMARK: When disconnecting the unit, the commands sequence will NOT be lost.
It is possible to execute a specific DiSEqC program using a direct access key
(see '4.13 Direct Access to Functions'). This enables you to change specific
configurations from the Spectrum Analyser Mode, useful during the parameter
adjustment process in an installation.
06/2005
Premium
[31].
[31] repeatedly until you have positioned the cursor on the
[31] repeatedly
Page 89

Publicidad

Tabla de contenido
loading

Tabla de contenido