Eaton xChargeIn Serie Manual De Instalación página 276

Estación de carga para vehículos eléctricos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 320
Mounting and installation instructions
Caution
Property damage due to dampness and moisture!
● The installation and commissioning of the charging station must take
● Only a vertical installation of the charging station is permitted. The
● The joints between the wall/floor-mounted column and the charging sta-
● Do not subject the charging station to high humidity for a longer period of
● If a cold charging station is brought into a significantly warmer environ-
● The only permissible places to mount the charging station are against a
● The charging station must always be equipped entirely and properly with
Caution
Risk of breaking the plastic housing!
● Countersunk screws may not be used for the mounting.
● Four of the supplied washers must be used under the nuts.
● Do not tighten the mounting screws with force.
● The mounting surface must be completely flat. Warpage of the housing
● If adjustment is necessary, the remaining four washers supplied must be
276
place in a suitable environment. The charging station must be protected
against rain, snow and dirt during the process. If installed outdoors, the
connection panel cover is not permitted to be opened in case of rain,
wind or snow.
charging station must be mounted with the supplied washers at a 90°
angle to the mounting surface - no inclination is allowed, otherwise water
drainage will not be possible and damage to the device will result (see il-
lustration below).
tion must not be sealed with silicone. Water must be able to drain off be-
hind the charging station (see figure above). If water drainage is not pos-
sible, this leads to damage to the device.
time.
ment (e.g. after longer transport in a cold environment), condensation
moisture may form in the device.
Before connecting the charging station to the power supply, you must
wait until the temperature of the charging station is the same as the
room temperature and the moisture has evaporated again.
wall or floor-mounted column. On the back side of the charging station,
there are culverts that allow condensation liquid to escape to the out-
side. To ensure that no splash water can get into the device, the rear
side of the charging station must be entirely protected.
the supplied cable glands. Unused cable insertion openings must be
screwed closed with blind plugs to ensure the necessary leak tightness.
must be prevented.
used.
xChargeIn
Installation manual V1.05
© EATON

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido