Connections and wiring
Fig. 7-16: Connection to a three-wire IT system with 230 V
7.4
Enable input X1
This function is not available with xChargeIn A Series.
The enable input X1 is equipped for use with a potential-free contact. Using
the enable input, it is possible to control the charging station using external
components (e.g. Eaton xComfort Building Automation System, external key
switches, house control, photovoltaic system, ...). The terminal is designed
as a spring-type terminal.
Open
Closed
The use of the enable input must be activated with a DIP switch setting
(DSW1.1 to ON), see
In addition to the DIP switch setting, starting a charging process using an en-
able input is dependent on the RFID authorization. The table shows under
which conditions charging is enabled.
288
Enable contact
8.1 DIP switch
RFID
DSW 1.1
Off
OFF
Permanent charging enabled − charging is possible at all times.
Off
ON
Charging enabled when X1 is closed.
State of the charging station
Locked
Ready for operation
settings.
Description
Installation manual V1.05
xChargeIn