Connections and wiring
Pin
1 (Tx+)
2 (Tx−)
3 (Rx+)
4 (Rx−)
Terminal data
Inflexible cable
Cat 5e / Cat6 STP
Cat 6 STP
Flexible cable
Cat 5e / Cat 6 STP
Preparing the connection cable
To prepare the connection cable, proceed as follows:
1) Strip the connection cable about 6 cm.
2) Knock back approx. 1 cm of shielding all over and wrap with conductive

Connecting the cable

To connect the cable, proceed as follows:
1) Fix the connecting cable at the point of the wrapped-around shielding
2) Tighten the shield clamp.
3) Clamp the wires to the terminal block [ETH] using an insertion tool.
292
-568A
-568B
Pair
Pair
3
2
3
2
2
3
2
3
Category
textile adhesive tape.
braid in the shield clamp [K].
-568A
Color
white/green
stripe
green/white
stripe or green
white/orange
stripe
orange/white
stripe or orange
Wire diameter
0.36 mm (AWG 27)
0.4 – 0.64 mm
(AWG 26 – AWG 22)
0.51 – 0.81 mm
(AWG 24 – AWG 20)
7 x 0.2 mm
(AWG 24)
xChargeIn
-568B
Color
white/orange stripe
orange/white stripe
or orange
white/green stripe
green/white stripe
or green
Insulation diameter
0.7 – 0.75 mm
0.7 – 1.4 mm
1.0 – 1,4 mm
1.1 – 1.4 mm