SL230.T - SL230.T.120
7. Description of the LEDs in the circuit.
Abbreviation
Description
DL1
Displays the status of input P.IN (terminal number 1).
If not engaged, the LED remains on.
Used for opening and closing safety devices, otherwise jumper between terminal COM and P.IN
DL2
Displays the status of input SEQ (terminal number 2).
If not engaged, the LED remains off.
Used to control the sequential opening (opens, stops, closes, stop) or start (opens, closes).
DL3
Displays the status of input STOP (terminal number 3).
If not engaged, the LED remains on.
Used to control the gate stopping devices, otherwise jumper between terminal COM and STOP
DL4
Displays the status of input PED (terminal number 4).
If not engaged, the LED remains off.
Used to control the partial opening of the gate (pedestrian)
DL5
Displays the status of input SCL (terminal number 5).
If not engaged, the LED remains on.
Used for closing safety devices, otherwise jumper between terminal COM and SCL.
DL6
Displays the status of input SOP (terminal number 6).
Using the non resistive sensitive edge with DSW2 Dip switch 1 set to OFF, if not engaged, the LED remains on, otherwise jumper
between terminal COM and SOP.
Using the 8K2 resistive sensitive edge with DSW2 Dip switch 1 set to ON, if not engaged, the LED remains on, otherwise set DSW2
Dip Switch 1 to OFF and jumper between terminal COM and SOP.
DL7
Displays the status of input LSC left limit switch (terminal number 7).
If not engaged, the LED remains on
DL8
Displays the status of input LSO right limit switch (terminal number 8).
If not engaged, the LED remains on
DL.S
Displays the programming and test status.
If not engaged, the LED remains off.
8. Push buttons in the circuit.
Abbrevia-
Description
tion
P1
Travel learning push button
P2
Remote controls learning push button
9. Preliminary check.
After powering up the control unit the DL.S LED comes on for a second.
Check the input diagnostics LEDs DL1, DL3, DL5, DL6, DL7 and DL8 are on.
If one of the normally closed contacts or one of the normally open contacts is not in the rest status, the limit switch learning operation cannot be carried
out and the DL.S LED flashes quickly to indicate a possible fault.
Should one of the safety inputs P.in, STOP, SCL, SOP not be used, insert a jumper between COM and the input not being used.
10. Programming and deleting the remote control.
The maximum storage capacity is 250 rolling code remote control codes.
Caution: The remote controls can only be saved and deleted when the gate is stationary.
Programming the button of the remote control associated with input SEQ.
1. Press push button P2 and hold it down until LED DL.S (PRG) starts to flash (1
2. Release push button P2.
3. Within 10 seconds, activate the remote control button to be learnt and associated with the sequential or start control.
4. Learning procedure completion will be signalled by the flashing of the flashing lamp, followed by the LED DLS that stops flashing.
5. Repeat the process for every remote control to be learnt.
Programming the button of the remote control associated with input PED for use as 2
Programming the button of the remote control associated with input P.OUT for use as 2
1. Press push button P2 and hold it down. LED DL.S starts to flash (1
2. Do not release push button P2 until it flashes faster (2
3. Release push button P2.
4. Within 10 seconds, activate the remote control button to be learnt and associated with the pedestrian control.
5. Learning procedure completion will be signalled by the flashing of the flashing lamp, followed by the LED DL.S that stops flashing.
6. Repeat the process for every remote control to be learnt.
22
flashing frequency).
st
flashing frequency).
st
flashing frequency).
nd
EN
channel when DSW1 Dip switch 8 is ON.
nd
channel when DSW1 Dip switch 8 is OFF.
nd