Testing The Automatic Gate System; Trimmer For Adjustments - Vimar SL230.T Manual De Instrucciones Para La Conexión Y El Uso

Tarjeta de mando dip 230/120 vca para cancelas correderas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
SL230.T - SL230.T.120
Procedure for gate travel programming:
1. Begin the procedure with the gate closed.
2. Press push button P1 and hold it down until LED DL.S starts to flash.
3. Release push button P1.
4. Follow the programming phases shown in the figure.
5. Programming ends when LED DL.S stops flashing.
1st START
CAUTION!
START WITH THE GATE CLOSED.
THE FIRST START STARTS THE
LEARNING BY MOVING THE
MOTOR IN OPENING.
DECEL.ZONE
3rd START
THE THIRD START SETS THE
STARTING POINT OF CLOSING
DECELERATION.
If the gate movement turns out to be reversed, check the DSW1 dip switch 7, do not change the wiring of either the limit switch or the electric motor.
12.

Testing the automatic gate system.

It is necessary to test all the accessories connected to the control unit, especially the safety devices such as the sensitive edges and photocells.
Remember that the photocells reverse the movement of the gate only during closing and the sensitive edges and/or internal photocells, if engaged
during opening, reverse the movement of the gate for 1.5 seconds, while if engaged when closing they fully re-open the gate.

13. Trimmer for adjustments

Trimmer
Function
TR1-DELAY
Pause time
TR2-TORQ
Motor torque
TR3-BRK
Braking intensity
TR4-SL
Slowdown speed
Obstacle sensitivity
TR5-SENSE
(only with Encoder)
24
DECEL.ZONE
2nd START
THE SECOND START SETS THE
STARTING POINT OF OPENING
DECELERATION.
ONCE IT REACHES THE CLOSING LIMIT
SWITCH, THE GATE RESUMES
OPENING.
ONCE PARTIAL OPENING IS FIXED, THE GATE RESUMES CLOSING.
COMPLETE CLOSING AND THE DL.S LED TURNING OFF INDICATE THE END OF PROGRAMMING
Description
With DSW1 Dip switch 1 ON, it adjusts the amount of time during
which the gate remains stationary before automatic closing.
It adjusts the electromechanical motor.
It adjusts the braking intensity of the motor during stopping phases.
It adjusts the deceleration speed.
If turned completely clockwise, deceleration is excluded
Function only available for motor models with Encoder. It adjust the
impact sensitivity.
EN
ONCE IT REACHES THE OPENING LIMIT
SWITCH, THE GATE RESUMES CLOSING.
4th START
THE FOURTH START SETS THE
PARTIAL OPENING POINT
(PEDESTRIAN)
Range
From 1 to 140 seconds, maximum,
clockwise
From 20 to 100%, maximum,
clockwise
From 0 to 100%, maximum,
clockwise
From 30 to 80%, maximum, anti-
clockwise
From 100 to 10%, maximum,
clockwise

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sl230.t.120

Tabla de contenido