SL230.T - SL230.T.120
14. Dip switch functions.
Number
Status
Function
OFF
Automatic closing disabled
DIP 1
ON
Automatic closing enabled
OFF
Operating logic: Opens-Stops-Closes-Stops
DIP 2
ON
Operating logic: Opens-Closes
OFF
Courtesy function on photocell disabled
DIP 3
ON
Courtesy function on photocell enabled
OFF
Collective operating logic disabled
DIP 4
ON
Collective operating logic enabled
OFF
Pre-flashing disabled
DIP 5
ON
Pre-flashing enabled
OFF
Flashing built into the flashing lamp.
DIP 6
ON
Flashing controlled by the control unit.
OFF
Gate opens towards the Right
DIP 7
ON
Gate opens towards the Left
OFF
P.OUT 2
DIP 8
ON
P.OUT Safety test (Photo-test)
OFF
Non-resistive edge SOP
DIP 1
ON
8K2 resistive edge SOP
OFF
Soft Start disabled
DIP 2
ON
Soft Start enabled
15. Troubleshooting.
Problem
The automatic gate system does not
work
You cannot save the remote controls
The remote control does not work
You cannot enter travel programming
As soon as the gate starts it stops and
reverses
During slowdown, the gate stops and
reverses
The gate stops just before the limit
switch trips
Declaration of Conformity.
Vimar S.p.A. declares that the device complies the following directives:
2014/53/EU (RED)
2014/30/EU (EMC)
2014/35/EU (LVD)
2006/42/EC (Machinery Directive)
The full text of the EU declaration of conformity is on the product sheet available on the following website: www.vimar.com.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
remote control channel
nd
Cause
No mains supply
Blown fuses
Control and safety inputs not working
Safety device test failed
Triac operating control test failed
(Only for motor models with Encoder)
Motor not working properly
The limit switches remain activated.
The limit switches are not activated.
Batteries of the remote control discharged
Remote control not compatible with the first one
saved
Reached memory saturation
Batteries of the remote control discharged
Safety devices open
Low acceleration on starting
Slowdown speed too low
The limit switch does not work properly
Description
-
The open gate is
closed automatically after the pause time.
It modifies the operating sequence of inputs SEQ (sequential) and PED (pedestrian) also via
remote control.
-
Reduction to 3sec of the residual pause time after passing over photocells.
-
When opening the gate, it ignores any controls and reloads the pause time when on pause
-
The flashing lamp starts flashing 3 seconds before the start of each movement
It configures the output for flashing lamps with independent flashing.
It configures the output for flashing lamps without independent flashing.
Configures gate opening towards the right
Configures gate opening towards the left
Input P.OUT works as 2
radio channel
nd
Input P.OUT controls the operation of the safety devices
SOP input configured to connect a non-resistive sensitive edge.
SOP input configured to connect an 8K2 resistive sensitive edge.
The gate begins moving at constant speed
The gate begins moving at a progressive speed
Solution
Check the power line switch
Replace the fuses with others of the same value
Check the diagnostics LEDs: DL1 P.IN, DL3
Check the operation of the safety devices installed if 4 simultaneous flashes of the following occur:
LED DL.S, indicator light and flashing lamp.
Replace the control unit if 2 simultaneous flashes of the following occur: LED DL.S, indicator light
and flashing lamp.
(Only for motor models with Encoder) Replace the motor if 3 simultaneous flashes of the following
occur: DL.S LED, indicator light and flashing
Check the capacitor and/or wiring of the board/motor and/or the presence of any obstacles in
deceleration zones if 6 simultaneous flashes of the following occur: DL.S LED, indicator light and
flashing lamp.
Check the fixing of the limit switch cams and/or whether you have closed the release if 7
simultaneous flashes of the following occur: LED DL.S, indicator light and flashing lamp.
Replace the batteries
The first saved rolling-code remote control configures the control unit to save only rolling-code
remote controls and not hard coded remote controls.
Delete at least one remote control or add an external receiver (maximum capacity 250 rolling-code
remote control codes)
Replace the batteries
Check the diagnostics LEDs: DL1 P.IN, DL3
Increase the TR2 TORQ trimmer
Increase the TR4 SL trimmer
Advance the limit switch cam
EN
STOP, DL5 SCL, DL6 SOP
must be on.
lamp.
STOP, DL5 SCL, DL6 SOP
must be on.