Subdrive 15 Connect/Subdrive 20 Connect - Franklin Electric SubDrive Connect Serie Manual De Usuario/Instalador

Ocultar thumbs Ver también para SubDrive Connect Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS

SubDrive 15 Connect/SubDrive 20 Connect

SubDrive 15 Connect/SubDrive 20 Connect
NEMA 3R
Model
(indoor/outdoor)
Voltage
Phase In
Frequency
Current (max)
Input from
Power Factor
Power Source
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Frequency Range
Output to
Motor
Current (max)
Wire Gage Size(s)
Factory Preset
Pressure
Setting
Adjustment Range
Temperature
Operating
(at 230 VAC input)
Conditions*
Relative Humidity
Temperature
Storage**
Shelf Life
Dimensions
NEMA 3R
and Weight
* Operating temperature is specified at full output power when installed as recommended. Refer to
"Over Temperature Foldback" on page 34
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
52
SubDrive 15
5870205103C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
12 A
~ 0.95
4 Watts
2.5 kW
Refer to
"Fuse/Circuit Breaker and Wire Sizing" on
page
20.
272 VAC Maximum
Single-Phase (3-Wire) OR Three-Phase
30-78 Hz: 1/2-rated pump (Three-Phase)
30-70 Hz: 2/3 or 3/4-rated pump (Three-Phase)
30-60 Hz: Matched pump (Three-Phase)
30-63 Hz (Single-Phase Motors)
5.9 A / phase
Refer to
"Maximum Motor Cable Length" on
page
21.
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)
.
SubDrive 20
5870205303C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
19 A
~ 0.95
5 Watts
4.2 kW
Refer to
"Fuse/Circuit Breaker and Wire Sizing" on
page
20.
272 VAC Maximum
Single-Phase (3-Wire) OR Three-Phase
30-78 Hz: 1/2-rated pump (Three-Phase)
30-70 Hz: 2/3 or 3/4-rated pump (Three-Phase)
30-60 Hz: Matched pump (Three-Phase)
30-63 Hz (Single-Phase Motors)
8.1 A / phase
Refer to
"Maximum Motor Cable Length" on
page
21.
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido