SubDrive 30 Connect/SubDrive 50 Connect

NEMA 3R
Model
(indoor/outdoor)
Voltage
Phase In
Frequency
Current (max)
Input from
Power Factor
Power Source
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Output to
Frequency Range
Motor
Current (max)
Wire Gage Size(s)
Factory Preset
Pressure
Setting
Adjustment Range
Temperature
Operating
(at 230 VAC input)
Conditions*
Relative Humidity
Temperature
Storage**
Shelf Life
Dimensions
NEMA 3R
and Weight
* Operating temperature is specified at full output power when installed as recommended. Refer to
"Over Temperature Foldback" on page 34
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
SubDrive 30
5870205403C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
23 A
~ 0.95
5 Watts
4.2 kW
Refer to
"Fuse/Circuit Breaker and Wire Sizing" on
page
20.
272 VAC Maximum
Single-Phase (3-Wire) OR Three-Phase
30-78 Hz: 1/2-rated pump (Three-Phase)
30-70 Hz: 2/3 or 3/4-rated pump (Three-Phase)
30-60 Hz: Matched pump (Three-Phase)
30-63 Hz (Single-Phase Motors)
10.9 A / phase
Refer to
"Maximum Motor Cable Length" on
page
21.
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)
.
SubDrive 30 Connect/SubDrive 50 Connect
SubDrive 50
5870205503C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
36 A
~ 0.95
7 Watts
7.2 kW
Refer to
"Fuse/Circuit Breaker and Wire Sizing" on
page
20.
272 VAC Maximum
Single-Phase (3-Wire) OR Three-Phase
30-78 Hz: 1/2-rated pump (Three-Phase)
30-70 Hz: 2/3 or 3/4-rated pump (Three-Phase)
30-60 Hz: Matched pump (Three-Phase)
30-63 Hz (Single-Phase Motors)
17.8 A (three-phase), 17.0 A (single-phase)
Refer to
"Maximum Motor Cable Length" on
page
21.
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-1/8" x 15-3/8" x 11-1/2" : 31 lbs
(66 x 39 x 29 cm) : (14.1 kg)
SPECIFICATIONS