(6) Upon first use of the analyzer, the message "REPEAT CALIBRATION" appears after a successful self check. Press the
"No" key to attain Ready-to-Measure status. This also happens if the instrument is not used for more than
seven days. To bring the instrument to Ready-to-Measure mode, insert the paper and execute the
calibration.
ATTENTION: If Combur
!
the Control-Test M, because in this case, the instrument calibration is performed via the grey reference
field in the test strip tray.
(7) To set the language of your choice, press the key sequence "Menu/Setup 1/Setup 2/Setup 3/Language/Other"
(see Sections 3.2 and 3.3).
(8) The Urisys 1100 system leaves the factory with the default settings for Printer, Measure and Interface modes, Test Strip
Type, Units, Language, Date/time format (see Section 3.2) and Operator ID. If your laboratory works differently, individual
preferences can be entered via the menus.
(9) Calibrate the analyzer with Control-Test M (see Section 5) if you intend to use Combur
Power-off
We recommend that the analyzer be switched off at the end of each working day and that the mains adapter be unplugged
from the AC wall socket (see Section 7.1, Cleaning).
4.1

Modification for Combur

For readings with Combur
Section 11), which exactly matches the geometry of the shorter test strips. Set the desired strip type from the menu. After
pressing START to confirm, insert the Type "N" tray in the reader. The Urisys 1100 system is then ready (see Section 6).
ATTENTION: Combur
!
Urisys 1100 system does not then compensate for strong intrinsic urine coloration during reading, so that
occasional false-positive readings may be obtained.
ATTENTION: For Combur
!
Control-Test M. With these strips the reader is calibrated entirely through the reference pad in the tray.
Always ensure that the reference pad is clean and undamaged (see Section 7).
4.2

Operator ID

The Urisys 1100 software allows the activation/deactivation of the operator identification code, containing up to 12 alpha-
numeric characters. The Operator ID and Authentication mode can be activated in Setup 3.
ATTENTION: Please ensure that you have a barcode reader and/or an AT/PC keyboard prior to activation,
!
as you will need one for this function.
Normal
If activated, the operator ID is asked upon every restart of the system and coming out from sleep mode.
This operator ID can contain up to 12 alphanumeric characters and will be printed out together with the test results and
will be sent to the host.
40
Test or Combur
Test test strips are used, a regular calibration is not necessary with
7
5
Test and Combur
7
7
Test or Combur
5
Test test strips a Type "N" test strip tray is required (for an order number, see
7
Test and Combur
5
Test test strips do not have a compensation pad. Consequently, the
Test or Combur
Test test strips you do not need to calibrate regularly with
7
5
Gebrauchsanweisung V04 / Operator's Manual V04 / Manual de instrucciones V04
Test UX test strips for urinalysis.
10
Test Test Strips
5