Technical Data; General Data - Lenze E94AYCPM Instrucciones Para El Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4

Technical data

General data

4
Technical data
General data
Area
Order designation
Communication profile
PROFIBUS node
PNO identification number
Interfaces
Communication medium
Network topology
Number of slaves
Max. cable length
Baud rate for cable type A (EN
50170)
Voltage supply
Conformities, approvals
,
"Servo Drives 9400" hardware manual
Here you can find the ambient conditions and the electromagnetic
compatibility (EMC) specifications applying to the communication module.
36
Values
E94AYCPM
PROFIBUS DP−V1
PROFIBUS DP−V0
Slave
0x07A8
9−pole Sub−D socket
RS485
Line (without repeater), tree/line (with repeater)
Max. 31 (without repeater), max. 125 (with repeater)
1200 m (depending on the baud rate selected and the cable type
used)
9.6 kbps ... 12 Mbps (automatic detection)
External supply via 2−pole plug connector
l
"+": U = 24 V DC (20.4V−0% ... 28.8V+0%), I = 130 mA
l
"−": reference potential for external voltage supply
l
CE
l
EAC
l
UL
l
EDK94AYCPM DE/EN/FR/ES/IT 6.1

Publicidad

Tabla de contenido
loading

Tabla de contenido