Ingeteam
2.5. Specification table
Storage system input (DC)
Storage system voltage range
(1)
Extended operating voltage
(2)
Minimum operating voltage
(1)
Maximum charge/discharge current
Battery type
PV array input (DC)
PV array maximum power
Maximum input voltage
MPP Voltage range
Operating voltage range
(3)
Minimum voltage for rated power
Maximum short circuit current
Maximum inverter backfeed current to the array
MPPT
Number of strings
Strings per MPP
Maximum input current
Auxiliary grid/genset input (AC)
Rated voltage
Voltage range
Nominal frequency
Frequency range
Load current range
Generator or grid maximum power
Maximum transient current
Consumption grid output (AC)
Nominal power (up to 40 ºC)
Maximum continuous power
Power (25 ºC) 30 min, 2 min, 3s
Max. temperature for rated power
Maximum current
Maximum output fault current
Maximum output overcurrent protection
Rated voltage
(5)
Voltage range
Nominal frequency
(5)
Performance
Maximum efficiency
Euroefficiency
General data
Cooling system
Air flow
Weight
Measurements (height x width x depth)
Stand-by current
Operating temperature
Relative humidity (without condensation)
Protection class
Contamination class
Markings
EMC and safety regulations
60
48 ~ 300 V
48 ~ 420 V
40 V
50 A
6.5 kWp
550 V
300 ~ 450 V
300 ~ 550 V
300 V
22 A
0
A rms
20 A
230 V
172 ~ 264 V
50 / 60 Hz
40 ~ 70 Hz
0 ~ 13 A
11,500 W
52 A
3 KVA
3 kW
(4)
40 ºC
13
26
220 ~ 240 V
± 2%
50 / 60 Hz
95.5 %
95 %
45 m
43.3 Kg
470 x 360 x 320 mm
< 10 W
–20 ~ +65 ºC
0 ~ 95 %
IP65
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-
3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
3
3TL
48 ~ 300 V
48 ~ 420 V
40 V
50 A
Lead, Ni-Cd, Li-ion
6.5 kWp
550 V
300 ~ 450 V
300 ~ 550 V
300 V
22 A
0 A rms
1
1
2
2
2
2
20 A
230 V
172 ~ 264 V
50 / 60 Hz
40 ~ 70 Hz
0 ~ 13 A
11,500 W
52 A
3 KVA
3 kW
3,500 / 3,900 / 5,080 W
40 ºC
13
A
A
26
<
A rms (60 ms)
26
A rms
A rms
220 ~ 240 V
± 2%
50 / 60 Hz
95.5 %
95.1 %
Forced ventilation
/h
45 m
/h
3
3
18.3 Kg
470 x 360 x 180 mm
< 10 W
–20 ~ +65 ºC
0 ~ 95 %
IP65
2
2
ABH2013IQM01_A - Installation and Operation Manual
Unit description
6
96 ~ 300 V
96 ~ 300 V
96 ~ 420 V
96 ~ 420 V
40 V
50 A
10 kWp
550 V
300 ~ 450 V
300 ~ 450 V
300 ~ 550 V
300 ~ 550 V
300 V
22 A
0 A rms
1
2
2
30 A
230 V
172 ~ 264 V
172 ~ 264 V
50 / 60 Hz
50 / 60 Hz
40 ~ 70 Hz
40 ~ 70 Hz
0 ~ 26 A
0 ~ 26 A
11,500 W
11,500 W
52 A
6 KVA
6 kW
6,400 / 6,900 / 7,900 W
40 ºC
26 A
< 40 A rms (60 ms)
40 A rms
40 A rms
220 ~ 240 V
220 ~ 240 V
± 2%
50 / 60 Hz
50 / 60 Hz
96 %
95.2 %
45 m
/h
45 m
3
65 Kg
470 x 360 x 180 mm
470 x 360 x 320 mm
< 10 W
–20 ~ +65 ºC
–20 ~ +65 ºC
0 ~ 95 %
0 ~ 95 %
IP65
2
CE
6TL
40 V
50 A
10 kWp
550 V
300 V
22 A
0 A rms
1
2
2
30 A
230 V
52 A
6 KVA
6 kW
40 ºC
26 A
± 2%
96 %
95.2 %
/h
3
23.3 Kg
< 10 W
IP65
2