Display control
20. Display control
INGECON SUN STORAGE 1PLAY inverters/chargers incorporate a display and keypad unit to interface with the
installer or the user.
This interface allows the display of the main internal parameters and the configuration of the entire system during
installation.
Parameters, variables and commands are organized as menus and submenus.
20.1. Keypad and LEDs
The keypad has four keys:
To exit a parameter, leave a menu and returning to the next level up in the structure, to not
confirm a change or not accept a suggestion.
Scroll up the list of parameters or folders within the same level or increase the value of an
editable parameter by one base unit. To increase the value of a parameter by intervals of 10
use the combination
combination
Scroll down the list of parameters or folders within the same level or decrease the value of an
editable parameter by one base unit. To reduce the value of a parameter by intervals of 10
use the combination
combination
Its purpose is to accept a parameter as valid, to enter a lower level menu in the structure, to
confirm a change or accept a suggestion.
The front panel has three LEDs:
Green LED
•
Flashing for 1 second: inverter checking the storage system and starting up.
•
On: inverter generating voltage in the consumption grid or connected to the auxiliary
grid/genset.
Orange LED
•
Three flashes: the external fan is not working correctly.
•
Flashing every 1 second: the internal fan is not running correctly.
•
Flashing every 3 seconds: the inverter is limiting power due to high temperature.
•
On: presence of alarm.
Red LED
•
On: manual shutdown.
ABH2013IQM01_A - Installation and Operation Manual
+
. To increase the value of a parameter by intervals of 100 use the
+
.
+
. To reduce the value of a parameter by intervals of 100 use the
+
.
Ingeteam
DE
EN
ES
FR
IT
PT
89