DIRECT CONNECTION + BOILER WITH 3 WAY VALVE
The circulation of the boiler activates if the temperature is over 50°C and no sanitary circuit is
required.
If the temperature of the sanitary boiler is lower than the sanitary SET temperature, the tempera-
ture of the boiler is greater than the sanitary SET, the 3 way valve switches to the boiler.
SYSTEM CONNECTION WITH BUFFER
The boiler can check loading of a buffer using a temperature probe positioned on the buffer. If the
temperature of the water in the boiler is over 50°C the cycle can start, The system heats the buffer
water, if the temperature of the boiler is over 5°C the temperature of the buffer, if lower the circula-
tor stops. To guarantee safety if the temperature of the water in the boiler exceeds 75°C the circu-
lator stays on. The system circulator P2 activates if the buffer temperature is over 50°C.
INSTALLATION
SAFETY DRAINAGE
VALVE
VALVE
ANTI-CONDENSATE 55°C
SAFETY DRAINAGE
VALVE
VALVE
ANTI-CONDENSATE
55°C
P2 = VALVE
THRE WAY
S2 = BUFFER
PROBE
P2 =
CIRCULATOR
SYSTEM
BUFFER
- 63
-