EdilKamin LAGUNA M 25 Instalación Uso Y Mantenimiento página 68

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 137
ERRORS AND DISPLAYS
DISPLAY
DESCRIPTION
Er01
Safety thermostat activation error (ask TSC for help)
Er02
Air pressure switch activation error (ask TSC for help)
Er03
Switch off error due to FLAME STOP
Er04
Water excess temperature error
Er05
Smoke excess temperature error
Er07
No smoke encoder signal error (ask TSC for help)
Er08
Smoke motor rotation adjustment problem error (ask TSC for help)
Er11
Internal clock error (ask TSC for help)
Er12
Switch on failed error
Er15
Temporarily no power supply error
Er16
Communication error with synoptic panel (ask TSC for help)
Er23
Boiler or buffer temperature probes error (ask TSC for help)
DISPLAY
DESCRIPTION
Probes
Status display of temperature probes. The message is displayed during
the Check up phase and indicates the temperature read on one or more
probes is equal to the maximum or minimum possible value.
Cleaning
The message indicates 500 working hours has been reached for USER
cleaning (see page 85).
To reset the message, use the RESET SERVICE function.
Switch on
The message appears if the system switched off non-manually during the
Block
Switch off phase, the system will only switch off when it has reached fully
operational mode.
Link Error
No communication between the keypad and the control board
USER MENU
On pressing the
By pressing the
Using the
key you can enter the sub-menu by obtaining the list or the parameter to change.
INSTRUCTIONS FOR USE
key you enter the first screen on the menu
Combustion Management
Heating Management
Chrono
Loading
Service Reset
and
key you scroll the menu highlighting the desired item.
- 68
-

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Laguna m 33

Tabla de contenido